== IMPORX CCTV ==
 
== IMPORX CCTV ==
  
Auto Tracking PTZ IP Kamera,Unterstützung Blue Iris,1080P Full HD 20X Optische Zoom Kamera ONVIF High Speed Wetterfeste Kamera,400ft IR Distanz,mit Heizlüfter und Wischer
+
[[File:CCTV-Cam-Kassel.jpg|300px]]
  
PART 1: connecting the cam to a windows PC
+
* Auto Tracking PTZ IP Kamera
the cam webinterface only works with Windows Internet Explorer (not edge, no mac, no linux)
+
* 1080P Full HD
connect cam directly via ethernet cable with pc, no internet needed
+
* 20X Optische Zoom
set your IP v4 address to 192.168.0.10 (gateway doesnt matter, set it to 192.168.0.1 )
+
* Wetterfeste mit Heizlüfter und Wischer
open internet explorer and connect to the cam by typing the following ip in the address bar: 192.168.0.99
+
* Infrarotlicht-Distanz: 120 m
the cam webinterface should appear, login: admin password: admin
+
* Mit [https://en.wikipedia.org/wiki/ONVIF ONVIF] und [https://blueirissoftware.com/ Blue Iris] Unterstützung
to activate the video click you need to install a custom internet explorer plugin. click 'download plugin' in center of interface (where video is supposed to be)
+
it will download from the cam (not internet) save to disk, install, restart browser (or refresh page)
+
video of the cam should be on now (some PC have security settings preventing to install the plugin, check windows settings to activate 'not save' software)
+
PART 2: set the cam to constantly auto tracking. this step is only neccessary with a brand new cam
+
go to the tracking tab (top right corner, little walking man)
+
use the arrow controls to make the cam point to the room (which would be straight down, if it hung vertically from a building)
+
enable zoom, set to 8 or 10
+
return 5 seconds
+
save scene
+
enable tracking, 'on'
+
the cam should be auto track movement now, test it.
+
to avoid the caming going into parking position doing nothing we need to go into system settings
+
  
go to the first tab in right panel, and save the current setting to scene 1
+
<br>
then go to left hand panel "system settings"
+
 
select 'PTZ' tab
+
== Connecting the Cam to a Windows PC ==
set return to parking to 5 min
+
 
change 'do nothing' to 'call scene 1'
+
* the cam webinterface '''only''' works with '''Windows Internet Explorer''' (not edge, no mac, no linux)
 +
* connect cam directly via ethernet cable with pc, no internet needed
 +
* set your IP v4 address to '''192.168.0.10''' (gateway doesnt matter, set it to 192.168.0.1 )
 +
* open Internet Explorer and connect to the cam by typing the following IP in the address bar: '''192.168.0.99'''
 +
* the cam webinterface should appear, login: '''admin''' password: '''admin'''
 +
* to activate the video you need to install a custom Internet Explorer plugin.
 +
** Click 'download plugin' in center of interface (where video is supposed to be)
 +
** it will download from the cam (not internet) save to disk, install, restart browser (or refresh page)
 +
** video of the cam should be on now
 +
** (some PC have security settings preventing to install the plugin, check windows settings to activate 'not save' software)
 +
 
 +
<br>
 +
 
 +
== Set the Cam to constantly Auto-Tracking ==
 +
 
 +
* go to the tracking tab (top right corner, little walking man)
 +
* use the arrow controls to make the cam point to the room
 +
** (which would be straight down, if it hung vertically from a building)
 +
* enable zoom, set to 8 or 10
 +
* return 5 seconds
 +
* save scene
 +
* enable tracking, 'on'
 +
* the cam should be auto track movement now, test it.
 +
* to avoid the cam going into parking position doing nothing we need to go into system settings
 +
** go to the first tab in right panel, and save the current setting to scene 1
 +
** then go to left hand panel "system settings"
 +
** select 'PTZ' tab
 +
** set return to parking to 5 min
 +
** change 'do nothing' to 'call scene 1'
 +
 
 +
<br>

Latest revision as of 09:16, 15 February 2021

IMPORX CCTV

CCTV-Cam-Kassel.jpg

  • Auto Tracking PTZ IP Kamera
  • 1080P Full HD
  • 20X Optische Zoom
  • Wetterfeste mit Heizlüfter und Wischer
  • Infrarotlicht-Distanz: 120 m
  • Mit ONVIF und Blue Iris Unterstützung


Connecting the Cam to a Windows PC

  • the cam webinterface only works with Windows Internet Explorer (not edge, no mac, no linux)
  • connect cam directly via ethernet cable with pc, no internet needed
  • set your IP v4 address to 192.168.0.10 (gateway doesnt matter, set it to 192.168.0.1 )
  • open Internet Explorer and connect to the cam by typing the following IP in the address bar: 192.168.0.99
  • the cam webinterface should appear, login: admin password: admin
  • to activate the video you need to install a custom Internet Explorer plugin.
    • Click 'download plugin' in center of interface (where video is supposed to be)
    • it will download from the cam (not internet) save to disk, install, restart browser (or refresh page)
    • video of the cam should be on now
    • (some PC have security settings preventing to install the plugin, check windows settings to activate 'not save' software)


Set the Cam to constantly Auto-Tracking

  • go to the tracking tab (top right corner, little walking man)
  • use the arrow controls to make the cam point to the room
    • (which would be straight down, if it hung vertically from a building)
  • enable zoom, set to 8 or 10
  • return 5 seconds
  • save scene
  • enable tracking, 'on'
  • the cam should be auto track movement now, test it.
  • to avoid the cam going into parking position doing nothing we need to go into system settings
    • go to the first tab in right panel, and save the current setting to scene 1
    • then go to left hand panel "system settings"
    • select 'PTZ' tab
    • set return to parking to 5 min
    • change 'do nothing' to 'call scene 1'